16 BIT DATA ACQUISITION BOARD
WITH 16 INPUT AND 2 ANALOG OUTPUTS
MODEL DAQ-16162-PCI
(NI PCI-6036E)
Features
Two 16-bit analog outputs, 8 digital
I/O lines, two 24-bit counters
NI-DAQ driver software to simplify
configuration and measurements
Four analog input signal ranges
NIST-traceable calibration certificate
Digital triggering
SPECIFICATIONS
Bus
Analog
Inputs
Resolution
Sampling
Rate S/s
Input
Range
Analog
Outputs
Resolution
Output
Rate
Output
Range
Digital
I/O
Counter/
Timers
Triggers
PCI
16 SE/8/DI
16 bits
200 kS/s
±.05
to±10V
2
16 bits
10 kS/s
±10V
8
2, 24-bit
Digital
10 kS/s
maximum when using the single ended DMA channel for for analog
ouput. 1 kS/s maximum when using the single DMA channel for
either for either analog input or counter / timer operation.
ANALOG
INPUT ACCURACY SPECIFICATIONS
Nominal
Range (V)
Absolute
Accuracy
Relative
Accuracy
%
of
Reading
Offset
(uV)
Noise
+ Quantizatiom (uV)
Temp
Drift
(%/C)
Absolute
Accuracy
at Full Scale (mV)
Resolutin
(uV)
Positive
FS
Negative
FS
24
Hrs
1
year
Single
Pt.
Averaged
Single
Pt.
Averaged
10.0
-10.0
.0646
.0688
1591.4
885.0
77.90
.0010
8.553
1025.20
102.50
5.0
-5.0
.0124
.0188
.66
38.90
38.90
.0005
1.787
512.60
51.26
.05
-.05
.0646
.688
.66
4.76
4.76
.0010
.4480
62.73
6.27
.05
-.05
.0646
.688
.93
2.57
2.57
.0010
.0660
33.80
3.38
Note: Accuracies are
valid measurements following internal calibration. Averaged
numbers assume dithering and averaging of 100 single readings.
Measurements accuracies are listed for operational temperatures
within ±1 degree C of internal calibration temperature
and ± 10 degrees of external or factory calibration temperature.
One year calibration interval recommended. The Absolute Accuracy
at Full Scale calculations were performed for a maximum range
input voltage, 10 (for example, 10V range for ± 10V range)
after one year, assuming 100 pt averaging of data.
Order
Code Model
Capacity
Range
Description
Price
Quantity
Add to